Pulse counting of norm-pulses over several channels with different options for triggering. Device operation and configuration via LCD display or via Ethernet interface.
Counter for TTL or NIM level pulses in stand-alone device or 2/12NIM housing.
- Max. frequency (periodic input signal): 200MHz
- Double pulse resolution: 5ns
- Individual gating of each channel or common gating (switchable on/off)
- Integrated basic logic processing (switchable ON/OFF)
- Common retrigger input
- Device operation and configuration via LCD display or via Ethernet interface